Department of Building
Permanent URI for this collectionhttps://irepos.unijos.edu.ng/handle/123456789/11545
Browse
2 results
Search Results
Item Assessment of Construction Errors in Reinforced Concrete Beams(INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING, 2015-05) Afunanya, J.E.BSTRACT This research investigated using the finite element method the effects of construction errors in reinforced concrete beams. This was borne out of the need to investigate one of the many factors responsible for the failure of structures. The variable is the arrangement of tensile steel reinforcements and transverse shear links. Beam models in each series with the original design intent served as the control and are compared with two others each with a typical construction error in either tensile steel reinforcement or transverse shear links. Beam models are designed in accordance to Eurocode2 to fail either in shear or flexure. Analysis and discussion of results based on the ultimate loads sustained and load-displacement relationship are made. Results from simulated beam models indicate that a reduction in the effective depth of a beam model from 112mm to 105mm in the flexural series led to a 13.8% decrease in strength. In the shear series, the incorrect spacing of the entire transverse shear link at 150mmc/c against 130mmc/c used in the control model led to a 23% increase in strength. It is suggested that a high level of quality assurance be maintained during the construction process to limit the occurrence and effects of construction errorsItem Experimental Investigation into the Effects of Construction Errors in Reinforced Concrete Beams(International Journal of Scientific & Engineering Research, 2015-12) Afunanya, J.E; Tok, T.Y; Williams, F.NThis research investigated through experimental procedure the effects of construction errors in flexural and shear reinforcement of reinforced concrete (RC) beams. This was achieved by casting and testing fifteen RC beam specimens (1000 × 120 × 150mm) under the four point bending test in Heavy Structures Laboratory at Swansea University UK. The test variable is the arrangement of tensile steel reinforcements and transverse shear links. Beam specimens were categorized into two series according to their designed modes of failure i.e. flexural and shear. Flexural specimens were significantly reinforced in shear, to ensure flexural failure whist shear specimens were significantly reinforced in flexure to ensure shear failure. For each specimen series, three cast beam specimens served as the control whilst nine others (three for each construction error investigated) were cast with a construction error in either tensile steel reinforcement or transverse shear links. Analysis and discussion of results is based on the failure modes, ultimate loads sustained and load-deflection behaviour of beam specimens. Test results indicate that a reduction in the effective depth of specimens in the flexural series led to an 8.14% and 28.6% decrease in strength and ductility of beam specimens. For the shear series; the removal of a transverse shear link and the inclination of transverse shear links at 60° resulted in 14.1% and 10.6% decrease in strength and 12.8% and 20.9% decrease in ductility respectively
