Abstract
This study is the design and performance
simulation of a solar domestic hot water thermosyphon
system for Zaria Nigeria latitude 11.2 oN and longitude
7.8oN. The design method employed is the simulation
based method, where detailed mathematical models
representing the design procedure of each component
and whole system design is coded into a computer
program using MATLAB programming language. The
program was used to calculate collector design
parameters and system characteristics. The effect of
some collector design parameters such collector tube
diameter, absorber plate thickness and collector tube
center to center distance on the heat removal factor
were studied through an optimization program written
in Matlab programming language to determine their
optimal values using . The performance of the system
was simulated using TRNSYS 16 software based on the
optimal design parameters to predict the storage tank
and collector temperature at the end of an average
recommended day for each month of the year. The final
system configuration and size adopted (Table 2) based
on the result of the optimisation, reveals that storage
tank water temperature varies between 59 to 82 degrees
Celsius at the end of each day for all year round
performance for this location. This implies that a very
significant fraction of the system load of a monthly
average daily hot water demand of 0.1m3 set at 90oC is
made by the solar water heater indicating potentials in
reduction of family utility bill for heating water.