Repository logo
Communities & Collections
All of DSpace
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Z. S Johnson"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • No Thumbnail Available
    Item
    Conceptual Design and Performance Prediction of a Thermosyphon Solar Water Heating System using TRNSYS
    (International Journal of Engineering Research & Technology (IJERT), 2014-10) Z. S Johnson; G.Y Pam; K. M Peter
    This study is the design and performance simulation of a solar domestic hot water thermosyphon system for Zaria Nigeria latitude 11.2 oN and longitude 7.8oN. The design method employed is the simulation based method, where detailed mathematical models representing the design procedure of each component and whole system design is coded into a computer program using MATLAB programming language. The program was used to calculate collector design parameters and system characteristics. The effect of some collector design parameters such collector tube diameter, absorber plate thickness and collector tube center to center distance on the heat removal factor were studied through an optimization program written in Matlab programming language to determine their optimal values using . The performance of the system was simulated using TRNSYS 16 software based on the optimal design parameters to predict the storage tank and collector temperature at the end of an average recommended day for each month of the year. The final system configuration and size adopted (Table 2) based on the result of the optimisation, reveals that storage tank water temperature varies between 59 to 82 degrees Celsius at the end of each day for all year round performance for this location. This implies that a very significant fraction of the system load of a monthly average daily hot water demand of 0.1m3 set at 90oC is made by the solar water heater indicating potentials in reduction of family utility bill for heating water.

DSpace software copyright © 2002-2026 LYRASIS

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify