Department of Physics

Permanent URI for this collectionhttps://irepos.unijos.edu.ng/handle/123456789/11277

Browse

Search Results

Now showing 1 - 10 of 38
  • Item
    Evaluation of indoor background ionization radiation profile in some hospitals in jos plateau state Nigeria
    (Journal of Natural Sciences Research, 2012) D.I.Jwanbot; M.M. Izam1; G..G.. Nyam; .S. Agada
    Certain types of building materials are known to be radioactive. Exposure to indoor ionizing radiation like exposure to any other type of ionizing radiation results in critical health challenges. An evaluation of thebackground ionizing radiation profile within the radiological departments of Skane Radiodiagnostic Centre, Plateau State Specialist Hospital, and their immediate neighbourhood were carried out. These hospitals also d using gamma-scout (model GS2 with serial number A20). The radiation levels were: 2.063 mSv/yr for Skane Radiodiagnositic Centre indoor Plateau State Specialist Hospital indoor result was 2.444mSv/y, outdoor result was 2.002mSv/yr.
  • Item
    DESIGN AND CONSTRUCTION OF A LOW-COST HEARING AID
    (International Journal of Scientific & Engineering Research, 2013-09) Domtau, D.L; Chagok, N.M.D; Akparanta, P.H; Fom, T.P; Mado, S.D
    A low-cost hearing aid device was designed and constructed to produce an amplified sound for people with hearing loss. A 9V dc was used as the power supply. The condenser microphone was used as input transducer to pick up sound from the environment for conversion to electrical signal, NPN transistor (BC548C) along with three capacitors and five resistors were used as pre-amplifier.to amplify. The integrated circuit (IC) TDA2822M, available in 8-pin mini chip package and specially designed for portable power amplification was used for the amplification function. A 32 ohms ear phone was used as the output transducer to convert the amplified electrical signals back to sound. The computed current gain was 100. Rc was obtained as 3.3Ω, 𝐼𝐵 = 0.025𝐴, 𝐼𝐸 = 2.5𝐴, 𝑅𝐸 = 1.5Ω, the impendence 𝑍0 = 1.9Ω
  • Item
    DESIGN AND CONSTRUCTION OF A LOW-COST HEARING AID
    (International Journal of Scientific & Engineering Research, 2019-09) Domtau, D.L.1, Chagok, N.M.D.2, Akparanta, P.H.3, Fom, T.P.4, Mado, S.D.5
    A low-cost hearing aid device was designed and constructed to produce an amplified sound for people with hearing loss. A 9V dc was used as the power supply. The condenser microphone was used as input transducer to pick up sound from the environment for conversion to electrical signal, NPN transistor (BC548C) along with three capacitors and five resistors were used as pre-amplifier.to amplify. The integrated circuit (IC) TDA2822M, available in 8-pin mini chip package and specially designed for portable power amplification was used for the amplification function. A 32 ohms ear phone was used as the output transducer to convert the amplified electrical signals back to sound. The computed current gain was 100. Rc was obtained as 3.3Ω, 𝐼𝐵 = 0.025𝐴, 𝐼𝐸 = 2.5𝐴, 𝑅𝐸 = 1.5Ω, the impendence 𝑍0 = 1.9Ω. Index Terms: Design, construction, hearing aid, hearing loss, integrated circuit, low-cost, npn transistor
  • Item
    RIEMANNIAN LAPLACION FOMULATION IN OBLATE SPHEROIDAL COORDINATE SYSTERM USING THE GOLDENN METRIC TENSOR
    (2016-01) N.E.J. Omaghali; S.X.K. Howusu
    Abstract: Studies have shown that most planetary bodies, the sun and earth inclusive, are better described as oblate spheroids rather than spherical. In this paper, using the Golden Metric tensor, we derive the expression for the Riemannian Laplacian in Oblate Spheroidal coordinate systems by the method of tensor analysis. The derived expression for the Riemannian Laplacian in Oblate Spheroidal coordinate systems reduce to pure Newtonian Laplacian in the limit c0 and contains post-Newtonian correction terms of all orders c-2 . The result obtained here opens the way for applications of the Riemannian Laplacian to all bodies in the Spheroidal coordinate system
  • Item
    Prevalence and Variation of Refractive Anomalies among Patients in the Bingham University Teaching (ECWA Evangel) Hospital, Jos, Nigeria.
    (Journal of Biology, Agriculture and Healthcare, 2014) Felix B. Masok; Stephen D. Songden; Emeka E. Ike
    This work set out to investigate refractive anomalies among patients in the Bingham University Teaching Hospital, Jos. The results reveal how these refractive errors varied between male and female subjects at different age groups. A total of 950 subjects were examined for refractive errors; 531 males and 419 females. It was observed that 735 (77.37%) had various refractive errors. Myopia was observed in 373 (49.79%) of the subjects with the number of females being 204 (54.69%) making them more myopic than the males 169(45.31%). Hyperopia was observed in 385 (40.52%) of the population with the male being more hyperopic than the females 174 (45.19%). Astigmatism accounted for 359 (37.79%) of the subjects with females being more astigmatic than the males 168 (46.80%). Presbyopia was observed in 404 subjects with males 240 (59.41%) being more presbyopic than females 164 (40.59%).The refractive error had its peak within the 60 – 69 age group. This pattern of refractive errors could be attributed to exposure to various forms of light particularly the ultraviolet rays (e.g rays from television and computer screens). This agrees with the report made by Cogan and Kinsey (1947) and Emina and Kio (1997).
  • Item
    Predicted Impairment and Handicap from Exposure to SteadyState Broad-Band Industrial Noise
    (Advances in Physics Theories and Applications, 2013) Chagok, N.M.D; Fom, T.P; Izam, M.M; Domtau, D.L; Jwanbot, D.I.
    In this work, the empirical formula derived by Chagok and Gyang (2012)in conjunction to the AAO-1979 rule was used to predict values for the monaural impairment and the hearing handicap for exposure to steady-state broad-band industrial noise. The predicted values for the monaural impairment and the hearing handicap increase with exposure levels and therefore support the Equal Energy Hypothesis (EEH). The values of the hearing handicap are always higher than the corresponding values of the monaural impairment. The values of the monaural impairment and the hearing handicap show that all the values increase with sound pressure level, exposure time and age and that values of the impairment and handicap could be obtained for sound pressure level of 70dBA if the table is expanded to consider entries for higher ages and more exposures. Keywords: Monaural impairment, hearing handicap, noise, hearing loss, industries.
  • Item
    On the development of UJ-MaGT scientific calculator
    (The Proceedings of the Nigerian Academy of Science, 2020) Mafuyai, M. Yaks; Meshak, B. David; Salifu, S. Imaben; Daniel, N. Dawuk; Barnabas Benaiah
    Graphing is an important skill/knowledge required by almost every scientist, engineer and other professionals that require analysis of data to make sense of phenomena, relationships, etc. This important knowledge is learned right from secondary school through to advanced level of education and it is developed through the study of functions in mathematics and laboratory exercises in sciences, etc. At the secondary school level, learning to graph by hand is the most preferred and common practice in most countries in the African continent and other parts of the world. However, studies have shown that graphing by hand present numerous difficulties to science students due to its high “procedural load”. To reduce the procedural load, an algorithm called UJ-MaGT was developed and tested for effectiveness. Excellent result in time management, simplification and pedagogical change in graph plotting process was achieved with the help of UJMaGT. Currently, the algorithm has been incorporated into a scientific calculator.
  • Item
    Colour Vision Performance Test
    (Journal of Natural Sciences Research, 2013) Stephen Songden; Emeka Ike
    Abstract Colour vision is important in everyday life and colour vision deficiency generally lowers the quality of life. The objective of the study was to investigate colour vision performance through tests and measurements. The visual acuity tests were obtained using the Snellen letters while the Colour vision measurements were achieved through designed colour targets. A total number of 8 participants were tested. The results of the measurements further confirmed that having good visual acuity is necessary but not sufficient for good colour vision performance. Keywords: Colour Vision, Visual Acuity, Snellen Letters, Ishihara, Dvorine Colour Test, Performance
  • Item
    K levels in some commercially consumed food crops collected from some villages in Barkin Ladi LGA, Plateau State Nigeria
    (Nigerian Journal of Physics, 2013-06) D.I.Jwanbot; M.M. Izam; G.G. Nyam
    The specific activity concentrations and the derived Annual Effective Doses in food crops cultivated and consumed within and outside the study area were measured by using a multi-channel pulse analyzer (Canberra series 10 plus coupled to a 76mm x 76mmNaI(Tl) scintillation detector. The activity concentrations of 40K ranged from 153.92 ± 5.28Bq/kg to 41.59 ± 6.60Bq/kg with a mean value of 111.27 ± 4.65Bq/kg. The annual Effective Dose was also calculated and the values ranged from 25.00µSvy-1 to 10.23µSvy-1 with an average of 14.69µSvy-1. The discrepancies in the results might be attributed to geological factors such as soil formation, application of fertilizer and differences in the type of crops analyzed. Although the results obtained were within the standard limit and may not pose any health hazard. Keywords: Potassium-40, Food crops, Isotopes, Activity, Annual effective dose and Nigeria
  • Item
    INVESTIGATION OF OPTICAL RETURN LOSS (BACK-REFLECTION) IN OPTICAL FIBER TRANSMISSION LINKS
    (International Journal of Computer Science and Mobile Computing, 2018-05) J. Ilouno; M. Awoji; B. J. Akeredolu
    Optical Return Loss (ORL) is the total amount of light returned from an optical fiber relative to the injected light. ORL can adversely affect fiber optics systems which indirectly affects the quality of the fiber network. One of the effects of this loss (multiple reflections) contributes greatly to the noise levels at the optical detector. Optical Return Loss could be caused by intrinsic material scattering (Rayleigh scattering) and Fresnel reflection. This paper however, focuses on the investigation of ORL using an Optical Time Domain Reflectometer (OTDR) amongst Optical Continuous Wave Reflectometer (OCWR), Optical Low Coherence Reflectometer (OLCR), and Optical Frequency Domain Reflectometer (OFDR). The OTDR was able to establish the ORL in every portion of the fiber under test. An ORL average level of 72.54 dB was obtained over span length of 2.86709 – 2.868.11 km. This is beyond the acceptable tolerance level (32 dB) of both the transmission and receiving equipment suggesting serious problem with the links. By implication, ORL can be used to determine the overall efficiency or performance of a fiber plant