INVESTIGATION OF OPTICAL RETURN LOSS (BACK-REFLECTION) IN OPTICAL FIBER TRANSMISSION LINKS
No Thumbnail Available
Date
2018-05
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
International Journal of Computer Science and Mobile Computing
Abstract
Optical Return Loss (ORL) is the total amount of light returned from an optical fiber relative to the
injected light. ORL can adversely affect fiber optics systems which indirectly affects the quality of the fiber
network. One of the effects of this loss (multiple reflections) contributes greatly to the noise levels at the optical
detector. Optical Return Loss could be caused by intrinsic material scattering (Rayleigh scattering) and Fresnel
reflection. This paper however, focuses on the investigation of ORL using an Optical Time Domain
Reflectometer (OTDR) amongst Optical Continuous Wave Reflectometer (OCWR), Optical Low Coherence
Reflectometer (OLCR), and Optical Frequency Domain Reflectometer (OFDR). The OTDR was able to establish
the ORL in every portion of the fiber under test. An ORL average level of 72.54 dB was obtained over span length
of 2.86709 – 2.868.11 km. This is beyond the acceptable tolerance level (32 dB) of both the transmission and
receiving equipment suggesting serious problem with the links. By implication, ORL can be used to determine the
overall efficiency or performance of a fiber plant
Description
Keywords
Rayleigh scattering, Fresnel reflection, OTDR